High turbidity addressed with results that can be checked.

MR DIY XSOA · Terusan Bojongsoang, Baleendah, Bandung Regency

Sampled 25 January 2026 · Analysed 31 January 2026ARS internal testReport 06/ARS-01/I/2026
Coloured and clear water samples at the MR DIY XSOA installation
Visual documentation of samples before and after treatment at the site.
The requirement
“The water is cloudy and coloured. Please provide a solution so it becomes clean, clear, and suitable for daily needs.”
01

Water context

Samples: raw water and treated water from the outlet installation point

02

ARS solution

ARS HPFS 150 LPH was configured to address measured turbidity, colour, odour, manganese, iron, and suspended solids in the raw water.

03

Verification result

Internal report 06/ARS-01/I/2026 concludes that the raw-water sample did not meet the report’s clean-water benchmarks for the parameters tested, while the HPFS output did.

Measured evidence

The change, shown parameter by parameter.

The summary below reproduces selected values from the ARS internal test report. Values must be read with the sampling date, method, and water context.

ParameterBeforeAfter HPFSReport benchmark
TurbidityFAU840<3
Colourmg/L Pt-Co18010
OdourDetectedNot detectedNot detected
Manganesemg/L0.33<0.10.1
Iron (Fe)mg/L0.21<0.020.2
TSSmg/L711—
pH6.77.76.5–8.5

Scope note: this internal test applies only to the submitted samples and the parameters measured on the stated date. Water quality may change. Visual clarity alone does not establish drinking-water safety; microbiological and other relevant parameters require verification according to the intended use and applicable requirements.

ARS and MR DIY personnel with the HPFS installation in Baleendah
ARS personnel and the outlet PIC with the on-site ARS HPFS installation.

Sustaining performance

Installation is the start—not the finish.

ARS uses the initial test as a performance baseline. Follow-up service can then be planned around source-water changes, usage load, pressure and flow, equipment condition, operating records, and repeat testing when required.

  1. 01Record operating conditions and the initial result.
  2. 02Perform routine inspection, cleaning, backwash, or component service as applicable.
  3. 03Re-test relevant parameters when conditions, risks, or intended use require it.
Discuss a similar water issue

ARS case-study standard

Problem → measurement → design → verification → care.

Future projects will follow the same structure so readers can distinguish photographs, measured evidence, technical interpretation, and the plan for sustaining performance.